Описание

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With 1 plug connector M12, 8-pin
  • Multicode
  • Door monitoring output
  • Indication of the door position by LED
  • Monitoring output DIA
  • Approach direction A (default setting on delivery)
Approach direction Horizontal Can be adjusted in 90° steps Safety switchThe device may be operated only in conjunction with the actuator CET-A-.... Important: The actuator must be ordered separately. Multicode evaluationEvery suitable actuator is detected by the switch. Solenoid operating voltage
  • DC 24 V +10% -15%
Guard locking type
CET3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.
LED function display
LED StateStatus LED
LED DIADiagnostic LED
LED 1 rdilluminates when the solenoid is energized
LED 2 gnilluminates when door is closed
Additional connections
DIAMonitoring output (semiconductor)
OUT DDoor monitoring output
RSTReset input
Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. The category is dependent on the installation position of the safety switch: Dimension drawing Wiring diagram Block diagram CET: Transponder-coded safety switch with guard locking CET3-AP: Mounting and Setup CET3-AP (closed-circuit current principle) CET3-AP: Mounting auxiliary release with key CET3-AP CET3-AP: Mounting emergency release safety swith CET3-AP Dimension drawingWiring diagramBlock diagram Technical dataApprovals Mechanical values and environment
Housing material
Slide Stainless steel
Safety switch housing Die-cast aluminum
Weight
Net 1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mechanical life 1 x 106
Installation orientation Any
Degree of freedom
Z ±4 mm
Y ±5 mm
X ±5 mm
Ready delay 1 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M12, 8-pin
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 6500 N
Locking force FZh 5000 N
Electrical connection ratings
Operating voltage DC
UB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
LED 24 V DC -15% ... 10%
Current consumption
ICM 480 mA
IB 80 mA
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (solenoid operating voltage UCM) 0,5 ... 8 A
External (operating voltage UB) 0,25 ... 8 A
Power consumption
Solenoid max.12 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable 30V DC, 2A
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs OA/OB
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output OA / OB 1 ... 200 mA
Output voltage
High U(OA) / U(OB) UB-1,5V ... UB V DC
Low U(OA) / U(OB) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Risk time according to EN 60947-5-3
Single device max.400 ms
Switch-on time 400 ms
Discrepancy time
Both safety outputs max.10 ms
Monitoring output DIA
Type of output p-switching, short circuit-proof
Switching current
DIA 1 ... 50 mA
Output voltage
DIA 0,8xUB ... UB V DC
Switching delay from state change max.400 ms
Monitoring output OUT D
Type of output p-switching, short circuit-proof
Switching current
OUT D 1 ... 50 mA
Output voltage
OUT D 0,8xUB ... UB V DC
Switching delay from state change max.700 ms
Work area
Repeat accuracy R 10 %
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category
Head upward 3
Head downward or horizontal 4
Performance Level PL e
PFHD
Head downward or horizontal 3.1 x 10-9
Head upward 4.29 x 10-8
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Mission time 20 y
''